PLL0 Status register
MSEL | Read-back for the PLL Multiplier value. This is the value currently used by the related PLL. |
PSEL | Read-back for the PLL Divider value. This is the value currently used by the related PLL. |
RESERVED | Reserved. The value read from a reserved bit is not defined. |
PLLE_STAT | Read-back for the PLL Enable bit. When one, the related PLL is currently activated. When zero, the related PLL is turned off. This bit is automatically cleared when Power-down mode is activated. |
RESERVED | Reserved. The value read from a reserved bit is not defined. |
PLOCK | Reflects the PLL Lock status. When zero, the related PLL is not locked. When one, the related PLL is locked onto the requested frequency. |
RESERVED | Reserved. The value read from a reserved bit is not defined. |